{"product_id":"d4s-jp40-voltage-temperature-monitoring-notification-system","title":"Down4Sound D4S JP40 Voltage Temperature Monitoring \u0026 Notification System Battery","description":"\u003cp\u003e \u003c\/p\u003e \u003cp\u003eTHE IMPORTANCE OF THE REMOTE DISPLAY:\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eIn demanding conditions of high amperage discharge, fast charging, and extended high\u003cbr\u003eamperage discharge, it is important to monitor the battery to keep the battery from being\u003cbr\u003edamaged. If the battery is discharged below the minimum voltage the battery will be damaged,\u003cbr\u003eand such damage will cause the battery to lose performance and\/or cause a dangerous\u003cbr\u003eoperating condition which could result in personal injury, equipment damage, or death. The\u003cbr\u003esame is true if the battery is allowed to over heat, or be over charged. This remote tool is a way\u003cbr\u003eto monitor the battery’s operation within the specified parameters without a putting restrictive\u003cbr\u003eBattery Management System (BMS) that reduces the amount of control the user has over the\u003cbr\u003ebattery’s operation. As with all tools, it is only as effective as the user. If the warnings are not\u003cbr\u003eheeded, or ignored the battery may become damaged, and this will void the warranty.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eCONNECTION METHOD\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eThe remote monitor has 2 plugs, a Phone jack, and an 2 pin port. The phone jack is connected\u003cbr\u003efrom the remote monitor and the plug labeled “remote” on the face of the battery.\u003cbr\u003eThe 2 pin plug on the remote monitor can be used to connect the monitor to a 12V power\u003cbr\u003esupply, (Example: the cars ignition system.) as a alternate power supply to keep the remote\u003cbr\u003emonitor from using the battery’s power.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eINSTRUCTION FOR USE:\u003cbr\u003eConnect the battery with the remote monitor using the supplied cable.\u003cbr\u003eTo Change Voltage\/Capacity Display\u003cbr\u003eThe default mode of the voltage\/capacity display is the battery’s voltage. If the button\u003cbr\u003emarked “Voltage\/Capacity” is pressed, the display will change to the show the battery’s\u003cbr\u003ecapacity in percentage of remaining charge. If the button is pressed again, it will return to\u003cbr\u003ethe default display.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eTo Change The Temperature Display:\u003c\/p\u003e \u003cp\u003eThe default mode of the temperature display is in Fahrenheit (Fo). If the button marked\u003cbr\u003e“Temperature” is pressed, the display will change to the unit of Celsius (Co). If the button is\u003cbr\u003epressed again, it will return to the default display.\u003cbr\u003eREMOTE\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003eThe JP40 Remote Display ships in the default setting that allows for plug and play use with the\u003cbr\u003eJP40 battery. Initial programming is not required when you purchase this remote for use with\u003cbr\u003eJP40. However, this remote is also designed to be used universally with AGM, Li-Po, LTO and\u003cbr\u003eother LFP type batteries in many configurations. Although the programming details shown\u003cbr\u003ebelow are accessible, they are only applicable to the universal remote model, which includes\u003cbr\u003ethe voltage and temperature sending unit that can be used external to any battery. This will\u003cbr\u003enot allow for the accurate internal temperature readings you get from your JP40 Battery since\u003cbr\u003ethe sending unit is already inside the battery. The programming instructions are provided\u003cbr\u003ebelow for knowledge about these functions in case the menu is accessed accidentally, and the\u003cbr\u003esettings need to be corrected for accurate functionality of the remote display.\u003cbr\u003ePress and hold the “Menu” button for six (6) seconds to access the program mode. The display\u003cbr\u003ewill flash indicating it is in program mode. If no buttons are pressed within six (6) seconds the\u003cbr\u003eunit will automatically exit program mode.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eTo set battery type, enter program mode. Use the Buttons marked with the up and down arrows\u003cbr\u003eto select the correct battery type. The battery types available to select are as follows:\u003cbr\u003eL - Lithium Ion Batteries (Li-ion, Li-po) [ Cell Voltage is 3.6V-3.8V ]\u003cbr\u003eF - Lithium Iron Phosphate Batteries (LFP) [ Cell Voltage is 3.2V ]\u003cbr\u003eP - Lead Acid Batteries (AGM) [ Battery Voltage is 12V ]\u003cbr\u003et - Lithium Titanate Oxide Batteries (LTO) [ Cell Voltage 2.4V ]\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eOnce the battery type is selected, press the “Menu” button again to set the number of cells in\u003cbr\u003eseries. The display will once again flash,\u003cbr\u003eSet the number of cells in series using the up and down arrows as before.\u003cbr\u003eEXAMPLE: 3S - is set to 03\u003cbr\u003e4S - is set to 04\u003cbr\u003e5S - is set to 05.... Etc.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003eAfter six (6) seconds with no buttons pushed, the unit will exit program mode automatically. If\u003cbr\u003ethe setting are not correct, re-enter program mode and select the correct settings. If the remote\u003cbr\u003esetting are incorrect, the information displayed by the remote will also be incorrect.\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthorized Down4Sound dealer at JS Ultimate Sounds. Free shipping on orders $99+.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Down4Sound","offers":[{"title":"Default Title","offer_id":66828415696941,"sku":"JP40-MonitorNotification","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/8096\/4909\/files\/d4s-jp40-voltage-temperature-monitoring-notification-system-w_5c4b787d-dcad-424f-b6da-0873467b667f.jpg?v=1782675318","url":"https:\/\/www.jsultimatesounds.com\/products\/d4s-jp40-voltage-temperature-monitoring-notification-system","provider":"JS Ultimate Sounds","version":"1.0","type":"link"}